Product Details
In this section we have available all of our Downloadable documents
The following downloadable details are grouped by the buildings existing roof panel type. The group of details include examples of standard Hugger applications as well as, low eaves, high eaves, rakes…..etc
Each group has a list of the files that are included in that download group, both PDF and CAD. If you do not see a detail file that you are looking for, please call us, and we will be happy to help you find it.
The detail drawing files are Named specific to the new roof panel profile that is going to be installed over the existing roof panel type. For example:
Description
Trapezoidal SSR panel installed over R-Panel =
Vertical Rib SSR installed over R-Panel =
PBR Panel installed over PBR-Panel =
File Name
Low Eave- Trapezoidal SSR over R-Panel
Low Eave- Vertical Rib SSR over R-Panel
Low Eave- R-Panel over R-Panel
Product Detail Download Groups
Existing or Thru-Fastened Panel Group
Roof Huggers are designed to fit over Thru-Fastened panels, from our standard Model C which fits a typical 12″ on center panel with a ;max rib height of 1.5 x 4″ wide base to our Custom Parts.
The following files are in the download links:
Existing Expansion Joint – Generic | Hugger Attachment- Trapezoidal SSR over R-Panel | Rake End Wall- Trapezoidal SSR over R-Panel |
High Eave Non Vented- Generic | Hugger Attachment- Vertical SSR over R-Panel | Rake End Wall- Vertical SSR over R-Panel |
High Eave Vented- Generic | Lean To Step Detail- Generic | Rake to Wall- Trapezoidal SSR over R-Panel |
High Eave- R-Panel over R-Panel | Low Eave- R-Panel over R-Panel | Rake to Wall- Vertical SSR over R-Panel |
High Eave- Trapezoidal SSR over R-Panel | Low Eave- Trapezoidal SSR over R-Panel | Ridge Detail- Non Vented- Generic |
High Eave- Vertical SSR over R-Panel | Low Eave- Vertical SSR over R-Panel | Ridge Detail- Vented- Generic |
Hugger Lap Attachment – Standard R-Panel | Panel Fixity- Hugger w Hat on Hat-R-Panel | Valley Cross Section- Generic |
Hugger Attachment- Custom- Trapezoidal SSR over 6”-10″ R-Panel | Panel Fixity- Model-C w Integral SubRafter Hat | Valley Gutter- Generic |
Hugger Attachment- Custom- Vertical SSR over 7.2 Rib Panel | Pitch Break- Roof to Wall- Generic | Zone Grid Framing- Hugger Custom w Hat on Hat |
Hugger Attachment- R-Panel over R-Panel | Rake End Wall- R-Panel over R-Panel | Zone Grid Framing- Model C w Integral Sub Rafters |
Existing 24″ on Center Trapezodial SSR Roof Panel Installed on Low Clips
Roof Huggers are designed to fit over the Trapezoidal SSR panel, from our standard Model D which fits a typical 24” on center panel with a max rib height of 3”, to our Custom Parts that can be fabricated to fit over any rib spacing Trapezoidal Panel from 12”oc to 30” oc rib spacing, any rib height, and any custom height up to 10”.
The following files are in the download links:
Generic – Existing Expansion Joint | Generic – Valley Cross Section | Trapezoidal SSR over Trapezoidal SSR – Rake to Wall |
Generic – High Eave Non Vented | Generic – Valley Gutter | Vertical SSR over Trapezoidal SSR – High Eave |
Generic – High Eave Vented | Trapezoidal SSR – Huggers w Hat on Hat- Panel Fixity | Vertical SSR over Trapezoidal SSR – Hugger Attachment |
Generic – Hip Cross Section | Trapezoidal SSR – Huggers w Hat on Hat- Zone Grid | Vertical SSR over Trapezoidal SSR – Low Eave |
Generic – Hugger Attachment Detail | Trapezoidal SSR over Trapezoidal SSR – High Eave | Vertical SSR over Trapezoidal SSR – Rake to Wall |
Generic – Hugger Lap Attachment | Trapezoidal SSR over Trapezoidal SSR – Hugger Attachment | Vertical SSR over Trapezoidal SSR – Rake End Wall |
Generic – Ridge Detail- Non Vented | Trapezoidal SSR over Trapezoidal SSR – Low Eave | |
Generic – Ridge Detail- Vented | Trapezoidal SSR over Trapezoidal SSR – Rake End Wall |
Existing 24” On Center Trapezoidal SSR Roof Panel Installed on Tall/Standoff Clips, and Thermal Blocks or structural decking with rigid insulation over.
This specially designed Roof Hugger is to be used with existing Trapezoidal SSR roof panels that are installed on Tall/Standoff Clips or structural decking with rigid insulation over. Our standard Model T fits a typical 24” on center panel with a max rib height of 3”, or you may need a Custom Part that can be fabricated to fit over any rib spacing Trapezoidal SSR Panel from 12”oc to 30” oc rib spacing, any rib height and any custom height up to 10”.
The following files are in the download links:
Generic – Existing Expansion Joint | Generic – Valley Cross Section | Trapezoidal SSR over Trapezoidal SSR – Rake End Wall |
Generic – High Eave Vented | Generic – Valley Gutter | Trapezoidal SSR over Trapezoidal SSR – Rake to Wall |
Generic – Hip Cross Section | Generic – High Eave Non Vented | Vertical SSR over Trapezoidal SSR – High Eave |
Generic – Hugger Attachment Detail | Trapezoidal SSR – Huggers w Tabs & Hat on Hat- Zone Grid | Vertical SSR over Trapezoidal SSR – Hugger w Tab Attachment |
Generic – Hugger Lap Attachment | Trapezoidal SSR – Huggers w Hat on Hat- Panel Fixity | Vertical SSR over Trapezoidal SSR – Low Eave |
Generic – Lean To Step Detail | Trapezoidal SSR over Trapezoidal SSR – High Eave | Vertical SSR over Trapezoidal SSR – Rake End Wall |
Generic – Ridge Detail- Non Vented | Trapezoidal SSR over Trapezoidal SSR – Hugger w Tab Attachment | Vertical SSR over Trapezoidal SSR – Rake to Wall |
Generic – Ridge Detail- Vented | Trapezoidal SSR over Trapezoidal SSR – Low Eave |
Existing Vertical Rib Standing Seam Roof Panel with Various On Center Rib Spacing From 12” to 30”
Roof Huggers are designed to fit over existing Vertical Rib panel types. Our Custom 2.75” Huggers can be fabricated to fit over any rib spacing Vertical Rib Panel from 12”oc to 30” oc rib spacing, any rib height and any custom height up to 10”. They are also available for Vertical Rib Systems that are installed with Standoff Clips
The following files are in the download links:
Generic- Existing Expansion Joint | Generic- Valley Gutter Detail | Vertical SSR over Vertical SSR- High Eave |
Generic- High Eave – Non Vented | 2.75” Huggers w Hat on Hat- Panel Fixity | Vertical SSR Rib Panel- Hip Detail |
Generic- High Eave- Vented | 2.75” Huggers w Integral Sub-Rafters- Zone Grid | Vertical SSR- Hugger Lap Attachment |
Generic- Hip Cross Section | Trapezoidal SSR over Vertical SSR- High Eave | Vertical SSR over Vertical SSR- Hugger Attachment |
Generic- Lean To Step Detail | Trapezoidal SSR over Vertical SSR- Hugger Attachment | Vertical SSR over Vertical SSR- Hugger w Tab Attachment |
Generic- Low Eave Detail | Trapezoidal SSR over Vertical SSR- Hugger w Tab Attachment | Vertical SSR over Vertical SSR- Low Eave |
Generic- Ridge Non-Vented Detail | Trapezoidal SSR over Vertical SSR- Low Eave | Vertical SSR over Vertical SSR- Rake End Wall |
Generic- Ridge Vented Detail | Trapezoidal SSR over Vertical SSR- Rake to Wall | Vertical SSR over Vertical SSR- Rake to Wall |
Generic- Valley Cross Section Detail | Vertical SSR- Huggers w Hat on Hat- Zone Grid | Vertical SSR- Valley Detail |
Existing Corrugated Roof Panels
Roof Hugger parts are designed to fit over this existing panel type. Our Custom Corru-Fit Hugger system is adaptable to the different rib center spacings of these panels. It is also a good choice with an existing 7.2 Rib panel, Mini Rib Panel, “B” Deck, and other various situations that have tight rib spaced panels.
The following files are in the download links:
Corru-Fit- Ridge Non Vented | Generic Panel over Corru-Fit- Low Eave | Trapezoidal SSR over Corru-Fit- Corru-Fit- Hugger Attachment |
Corru-Fit- Valley Gutter Detail | Generic- Hip Detail | Trapezoidal SSR over Corru-Fit- High Eave |
Corru-Fit Huggers w Hat on Hat- Zone Grid | Generic- Hip Cross Section | Trapezoidal SSR over Corru-Fit- Low Eave |
Generic- Valley Detail | R-Panel over Corru-Fit- Corru-Fit- Hugger Attachment | Trapezoidal SSR over Corru-Fit- Rake End Wall |
Generic- Ridge Vented | R-Panel over Corru-Fit- High Eave | Vertical SSR over Corru-Fit- Corru-Fit- Hugger Attachment |
Generic- Low Eave Detail | R-Panel over Corru-Fit- Rake End Wall |
Specifications
Literature Downloads
DISCLAIMER:
Roof Hugger, LLC is a component manufacturer and as such does not include project engineering with it products. Roof Hugger, LLC has however done extensive testing of its products by independent third party engineering and testing firms and makes that information available for review by design professionals for their exclusive usage.
Users of the provided information which includes but is not limited to system capacities, load tables, cad details, grid assemblies, product specifications, etc., assume full responsibility for all design decisions made relating to the suitability of use. Users must rely on their own judgement or that of a design professional when determining how to best apply the data provided. Users agree that Roof Hugger, LLC is under no obligation to provide additional details, testing or test data on their behalf.
Information regarding systems having received Florida Product Approval is also included. The assembly information for each approval is very specific as to the existing panel, the new panel, the sub-framing system and components used. Deviation from the approved assembly, however slight, will void the approval and necessitate specific project engineering. The use of a Florida Product Approval number is the sole responsibility of the design professional. Roof Hugger, LLC assumes no liability for the incorrect or inappropriate use of these approvals.
Roof Hugger, LLC shall not be responsible for claims, damages, injury or losses to you or third parties arising from your use of the information provided. It is also understood and agreed that any information provided herein cannot be reproduced, duplicated or distributed without the express written permission of Roof Hugger, LLC.